SINAMICS G120P Power Module PM230 with integrated Class B filter Protection class IP55/UL Type 12 3AC380-480V+10/-10% 47-63Hz Power low overload: 1.5kW at 150% 3S, 110% 57S, 100% 240S Ambient temperature -10 to +40°C (LO) 460x 154x 249 (HxWxD), FSA without Control Unit and operator unit approved for CU230P-2 from firmware version V4.3.2 Power Module SINAMICS Power Module PM230 Protection class IP55the specialist for building technology for the SINAMICS G120P frequency converter. The SINAMICS power unit, in combination with the appropriate CU230P-2 control unit and an IOP/IOP-2 (Intelligent Operator Panel) or Basic Operator Panel (BOP-2) control panel or optionally a blanking cover, creates a functional SINAMICS G120P frequency converter. The high degree of protection means that it can be used in harsh environments, for example at ambient temperatures of up to 60 degrees. The PM230 protection class IP55 generates only minimal network perturbations without additional measures and apparent power losses and ensures that faults are automatically acknowledged after a power failure. In addition to the energy benefits, the environment is also protected. The PM230 protection class IP55 power unit is available from 0.37 kW to 90 kW for wall mounting outside the control cabinet. Frame sizes FSA to FSF of the PM230 Power Module with protection class IP 55 are available with an integrated class A line filter for installations in accordance with category C2 and with an integrated class B line filter in accordance with category C1 in accordance with EN 61800-3. The following accessories are included as standard: shield plates and shield connection kits for the EMC-compliant connection of power and control cables, as well as connection plugs for the line and motor output for frame sizes FSA to FSC. SINAMICS - the comprehensive drive family for every application area
Property | Value |
Line voltage: | 380 to 480 V |
Max. Output frequency: | 550 Hz |
Use in industrial areas permitted: | yes |
Height: | 460 mm |
Width: | 154 mm |
Depth: | 249 mm |
Type of converter: | U-converter |
Max. output power with linear load at rated output voltage: | 1.1 kW |
4-quadrant operation possible: | no |
Relative symmetrical mains voltage tolerance: | -10 % |
Integrated brake chopper: | no |
Number of input phases: | 3 |
Use in residential and commercial areas permitted: | yes |
Relative symmetrical mains frequency tolerance: | 5 % |
Number of output phases: | 3 |
Max. output power at square load at rated output voltage: | 1.5 kW |
Nominal output current I2N: | 4.1 A |