SINAMICS G120 Control Unit CU250S-2 DP integrated PROFIBUS supported Vector control Simple positioner EPOS via license extended functions 4 configurable DI/DO 6 DI (3 F-DI), 5 DI 3 DO (1 F-DO) 2 AI, 2 AO Safety integrated STO, SBC, SS1 additional safety functions via license 'EXTENDED SAFETY' Encoder SS: D-CLiQ+HTL/TTL/SSI Resolver/HTL via terminal Protection class IP20 USB and SD/MMC interface Control Unit SINAMICS Control Unit CU250S-2 DP for high-performance applications in general mechanical engineering for the modular frequency converter SINAMICS G120. The Control Unit CU250S-2 is part of the modular frequency converter SINAMICS G120 (consisting of power unit, control unit, operator panel). The control unit is suitable for individual drives with higher requirements for speed control. Extended safety functions and a large I/O frame allow extensive applications. With vector control, two encoders (position and speed) can be connected. This extension enables use in lifting/swivelling/travel or rotary applications. The Control Unit CU250S-2 controls and monitors the power unit (Power Module) and the connected motor in several selectable control types. It enables communication with a local or central control system and with monitoring devices and is used to connect all process-relevant auxiliary units and external components such as sensors, valves, contactors, etc. The extensive I/O interfaces, the fieldbus interfaces and the additional software functions optimally support the application in general mechanical engineering. The CU250S-2 has the integrated safety functions Safe Torque Off (STO), Safe Stop 1 (SS1) and Safe Brake Control (SBC) as standard. In addition, the integrated safety functions Safely Limited Speed (SLS), Safe Speed Monitor (SSM) and Safe Direction (SDI) can be activated with the safety license. The following integrated communication variants are available: CU250S-2 with the protocols USS, Modbus RTU, CU250S-2 DP PROFIBUS as well as CU250S-2 PN PROFINET, EtherNet/IP and CU250S-2 CANopen. The control unit can be operated with the following SINAMICS power units: PM240-2 (0.55 kW to 132 kW) and PM240 (up to 250 kW). SINAMICS - the universal drive family for every application area
Property | Value |
Number of HW interfaces serial RS-485: | 1 |
Height: | 199 mm |
Width: | 73 mm |
Depth: | 67 mm |
Supports protocol for data highway: | no |
With optical interface: | no |
Supports protocol for LON: | no |
Supports protocol for AS-Interface Safety at Work: | no |
Supports protocol for TCP/IP: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for PROFINET IO: | no |
Supports protocol for PROFIBUS: | yes |
Supports protocol for EtherNet/IP: | no |
Supports protocol for INTERBUS-Safety: | no |
Supports protocol for SUCONET: | no |
Supports protocol for CAN: | no |
Supports protocol for KNX: | no |
Supports protocol for INTERBUS: | no |
Number of HW interfaces serial RS-232: | 1 |
Number of HW interfaces serial TTY: | 4 |
Supports protocol for other bus systems: | no |
Supports protocol for ASI: | no |
Supports protocol for SafetyBUS p: | no |
Supports protocol for MODBUS: | no |
Supports protocol for PROFIsafe: | yes |
Supports protocol for DeviceNet Safety: | no |
Supports protocol for SERCOS: | no |
Supports protocol for PROFINET CBA: | no |
Supports protocol for Foundation Fieldbus: | no |
Number of HW interfaces USB: | 1 |
With PC connection: | yes |
Number of analog outputs: | 2 |
Number of analog inputs: | 2 |
Number of digital outputs: | 3 |
Number of digital inputs: | 15 |
Supports protocol for BACnet: | no |
Protection class (NEMA): | 1 |