As a wire-guided mechanical room thermostat, the room temperature controllers are directly wired to a heating element. The wall unit is suitable for surface mounting. Eco-design-compliant use in conjunction with stationary infrared heating elements is not possible. Setting range 5-30°C, reduction, on/off switch, heating lamp, break contact, 230VAC, 10A, pure white similar to RAL 9010, operating voltage: 230 VAC, 50 Hz, hysteresis: approx. 0.5 K with a temperature change of max. 4 K / h, max. switching current: 10 A (2.2 kW), switching element: bimetal contact, on/off switch: yes, switching contact: break contact (max. 10 actuators), switching capacity: 2300 W, protection type: IP 30, protection class: II, dimensions 78x82x27mm. If the installed power exceeds the specified switching capacity of the respective room thermostat, the heating elements must be switched via additional load relays type LS-E.
Property | Value |
Type of power supply: | without |
Mounting type: | Surface-mounted |
Protection class (IP): | IP30 |
RAL number: | 9010 |
Height: | 82 mm |
Width: | 78 mm |
Depth: | 27 mm |
Heating: | yes |
Cooling: | no |
Number of heating outputs: | 1 |
With display: | no |
Operation: | Rotary |
Color: | cream white |
Contact type: | Opener |
Version: | On/Off |
Connection: | Two-wire |
With receiver: | no |
Measuring range lower value: | 5 °C |
Measuring range upper value: | 30 °C |
Sensor external: | no |
Thermal feedback: | parallel |
Control characteristics: | other |
Difference value: | 0.5 K |
Difference adjustable: | no |
Temperature readable: | no |
With noise level indicator: | no |
Sensor design: | Bimetal |
With drinking water circuit: | no |
Max. voltage of the contacts: | 230 V |
Max. Contact load: | 10 A |
Protection class (NEMA): | other |
Explosion-proof: | no |
Class of temperature controller: | I |